Paper 11.149

N. D. Daniell et al., "Criterion Validity of Whole Body Surface Area Equations: A Comparison Using 3D Scanning", in Proc. of 2nd Int. Conf. on 3D Body Scanning Technologies, Lugano, Switzerland, 2011, p. 149.

Title:

Criterion Validity of Whole Body Surface Area Equations: A Comparison Using 3D Scanning

Authors:

Nathan D. DANIELL 1, Tim OLDS 2,3, Grant TOMKINSON 2

1 ErgoLab, Mawson Institute, University of South Australia, Australia;
2 School of Health Sciences, University of South Australia, Australia;
3 Samsom Institute, University of South Australia, Australia

Abstract:

Measurements of whole body surface area (WBSA) have important applications in numerous fields including clinical medicine, biomechanics, and sports science. Currently WBSA is most often estimated using predictive equations due to the complex and time consuming methods required for direct measurements. As a result, many different predictive equations have emerged. The aim of this study was to identify whether there were significant and meaningful differences between WBSA measurements taken using a whole-body three-dimensional (3D) scanner (criterion measure) and the estimates derived from each of the WBSA equations identified from a systematic review. The study also aimed to determine whether differences varied according to BMI, sex or athletic status (using rowers as a comparison population). The systematic review identified 15 WBSA equations derived for Western adult populations which have been published since 1900. For this study, WBSA was measured on 1732 subjects using the Vitus Smart 3D scanner. This included 1452 subjects (753 males, 699 females) aged 18-30 years from the general population and 280 rowers (161 males, 119 females) aged 18-54 years. Mixed design ANOVAs determined whether the differences between the measured and equation-predicted values varied systematically with BMI category, sex or athletic status. Bland-Altman analysis was also used to identify the systematic error (bias) and random error (standard deviation of the differences). With a few exceptions, the equations were quite accurate (bias <2%) and precise (standard deviation of the differences 1.5-3.0%). Body mass index had a substantial impact on the accuracy and precision of WBSA equations. Significant differences were also identified for sex and athletic status, although the magnitude of these differences was minimal. Care must be taken when deciding which equation to use when estimating WBSA.

Keywords:

3D scanning, body surface area, anthropometry

Details:

Abstract: 11.149.pdf
Full paper: -
Proceedings: 3DBST 2011, 25-26 Oct. 2011, Lugano, Switzerland
Pages: 149
DOI: -

Copyright notice

© Hometrica Consulting - Dr. Nicola D'Apuzzo, Switzerland, www.hometrica.ch.
Reproduction of the proceedings or any parts thereof (excluding short quotations for the use in the preparation of reviews and technical and scientific papers) may be made only after obtaining the specific approval of the publisher. The papers appearing in the proceedings reflect the author's opinions. Their inclusion in these publications does not necessary constitute endorsement by the editor or by the publisher. Authors retain all rights to individual papers.

Proceedings of 3DBODY.TECH International Conferences on 3D Body Scanning & Processing Technologies, © Hometrica Consulting, Switzerland