I. Barbero-Garcia et al., "Automatic Low-Cost Tool for Head 3D Modelling and Cranial Deformation Analysis in Infants", in Proc. of 3DBODY.TECH 2019 - 10th Int. Conf. and Exh. on 3D Body Scanning and Processing Technologies, Lugano, Switzerland, 22-23 Oct. 2019, pp. 9-14, doi:10.15221/19.009.

Title:

Automatic Low-Cost Tool for Head 3D Modelling and Cranial Deformation Analysis in Infants

Authors:

Ines BARBERO-GARCIA 1, Jose Luis LERMA 1, Pablo MIRANDA 2

1 Photogrammetry and Laser Scanning Research Group, Universitat Politecnica de Valencia, Spain;
2 Hospital Universitari i Politecnic La Fe, Valencia, Spain

Abstract:

Cranial deformation is a problem that affects an important number of infants. It requires different treatments, varying from repositioning techniques to surgery depending on the leading cause. The evaluation of the deformation is usually carried out using simple but low-accuracy methodologies such as visual assessment and clinical measurements. Accurate methodologies such as radiological tests and combinations of cameras and scanner are available but they are invasive and/or costly.
A patent-pending smartphone-based photogrammetric tool for the analysis of cranial deformation is presented. The methodology allows the generation of head three-dimensional (3D) models of infants automatically. It is non-invasive, low-cost and can be operated by users without any photogrammetric knowledge.
The presented tool consists of a smartphone app, a coded cap that is fitted to the head of the infant and processing software that yields the 3D models.
The data acquisition can be easily carried out during the routine clinical consultation. The patient is held by an adult while the application is used to obtain the data around the infant's head. The process is similar to a video recording, and the app guides the user during the process. The tool can tolerate the patient's movement so no immobilization or sedation is required. The whole data acquisition process can be completed in a couple of minutes. After the acquisition stage, the data is processed to obtain a 3D model of the patient's head.
The accuracy and repeatability of the process have been tested under ideal conditions. The obtained accuracy was found to be better than 1 mm. The methodology has also been tested in real conditions obtaining models useful for the evaluation of different types of cranial deformation.
The tool can be easily implemented in clinical routine. It requires minimum resources and provides a significant improvement of the techniques currently used for cranial deformation assessment.

Details:

Full paper: 19009barberogarcia.pdf
Proceedings: 3DBODY.TECH 2019, 22-23 Oct. 2019, Lugano, Switzerland
Pages: 9-14
DOI: 10.15221/19.009

Copyright notice

© Hometrica Consulting - Dr. Nicola D'Apuzzo, Switzerland, www.hometrica.ch.
Reproduction of the proceedings or any parts thereof (excluding short quotations for the use in the preparation of reviews and technical and scientific papers) may be made only after obtaining the specific approval of the publisher. The papers appearing in the proceedings reflect the author's opinions. Their inclusion in these publications does not necessary constitute endorsement by the editor or by the publisher. Authors retain all rights to individual papers.