Paper 10.179

S. Raith et al., "Breast Volume Measurements Using 3-D Surface Imaging: a Standardized Validation of the Introduced Method and a Comparison to Classical Approaches", in Proc. of 1st Int. Conf. on 3D Body Scanning Technologies, Lugano, Switzerland, 2010, pp. 179-180, https://doi.org/10.15221/10.179.

Title:

Breast Volume Measurements Using 3-D Surface Imaging: A Standardized Validation of the Introduced Method and a Comparison to Classical Approaches

Authors:

Stefan RAITH, Maximilian EDER, Fee ARMBRECHT, Alexander VOLF, Laszlo KOVACS

Research Group Computer Aided Plastic Surgery - CAPS, Clinic for Plastic Surgery and Hand Surgery, Technical University Munich, Germany

Abstract:

Introduction: Precise and objective calculation of breast volume can be helpful to evaluate the aesthetic result of breast surgery, but traditional methods are unsatisfactory. Three-dimensional (3-D) scanning of the body surface allows reproducible and objective assessment of the complex breast region but requires further investigation before clinical application. The main goal of this study was to investigate the precision and accuracy of breast volume measurement using 3-D body scanning and to compare breast volume calculation with 3-D scanning and three classic methods, focusing on relative advantages, disadvantages, and reproducibility.
Materials and Methods: Five independent observers standardized the 3-D scanning method using two dummy models (n = 200) and examined its applicability with 6 test subjects and 10 clinical patients (n = 2220). Breast volume measurements obtained with the 3-D scanner technology were compared with reference measurements obtained from test subjects through MRI, thermoplastic castings and anthropomorphic measurements.
Results: The mean deviation of the breast volume measurements of one test subject by all observers, expressed as percentage of volume, was 2.86 +/- 0.98, significantly higher than the deviation for the dummy models, 1.65 +/- 0.42 (p < 0.001). Inter-observer differences in measurement precision were not statistically significant. The mean breast volumes obtained by MRI (441.42 +/- 137.05 cc) and 3-D scanning (452.51 +/- 141.88 cc) significantly correlated (r = 0.995, p < 0.001). MRI showed the highest measurement precision, with a mean deviation (expressed as percent of mean breast volume) of 1.56 +/- 0.52 compared to 2.27 +/- 0.99 for the 3D scanner, 7.97 +/- 3.53 for thermoplastic castings, and 6.26 +/- 1.56 for the anthropomorphic measurements. Breast volume calculations using MRI showed the best agreement to 3-D scanning measurement (r = 0.990), followed by anthropomorphic measurement (r = 0.947), and thermoplastic castings (r = 0.727).
Conclusion: Breast volume measurement using 3-D surface imaging represents a sufficiently precise and accurate method to guarantee objective and exact recording. Compared to three classical methods for breast volume calculation, 3D scanning allows precise measurement, better spatial interpretation of the anatomical area to be operated on (due to lack of chest deformation), non-invasiveness, and good patient tolerance.

Keywords:

breast volume measurements, standardization, 3-D scan

Details:

Extended abstract: 10.179.pdf
Full paper: -
Proceedings: 3DBST 2010, 19-20 Oct. 2010, Lugano, Switzerland
Pages: 179-180
DOI: https://doi.org/10.15221/10.179

Copyright notice

© Hometrica Consulting - Dr. Nicola D'Apuzzo, Switzerland, www.hometrica.ch.
Reproduction of the proceedings or any parts thereof (excluding short quotations for the use in the preparation of reviews and technical and scientific papers) may be made only after obtaining the specific approval of the publisher. The papers appearing in the proceedings reflect the author's opinions. Their inclusion in these publications does not necessary constitute endorsement by the editor or by the publisher. Authors retain all rights to individual papers.